Real-time hardware-in-the-loop approach for adaptive centralized protection schemes using clustering algorithms

annif.suggestionsrelays|networks (societal phenomena)|information networks|electrical power networks|distribution of electricity|microgrids|shielding|development (active)|data security|electrical engineering|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p19416|http://www.yso.fi/onto/yso/p5570|http://www.yso.fi/onto/yso/p12936|http://www.yso.fi/onto/yso/p7753|http://www.yso.fi/onto/yso/p187|http://www.yso.fi/onto/yso/p39009|http://www.yso.fi/onto/yso/p3601|http://www.yso.fi/onto/yso/p4230|http://www.yso.fi/onto/yso/p5479|http://www.yso.fi/onto/yso/p1585en
dc.contributor.authorPashaei, Meysam
dc.contributor.authorRastegar, Hasan
dc.contributor.authorZandrazavi, Seyed Farhad
dc.contributor.authorKauhaniemi, Kimmo
dc.contributor.authorLaaksonen, Hannu
dc.contributor.departmentVebic-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.orcidhttps://orcid.org/0000-0001-7113-8291-
dc.contributor.orcidhttps://orcid.org/0000-0002-7429-3171-
dc.contributor.orcidhttps://orcid.org/0000-0001-9378-8500-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2024-08-27T10:10:44Z
dc.date.accessioned2025-06-25T13:47:37Z
dc.date.available2024-08-27T10:10:44Z
dc.date.issued2024-07-18
dc.description.abstractThe main objectives of adaptive protection are isolating only the faulty network section and operating with varying network topologies and levels of generation. To accomplish this, the settings of protective devices may need to modify if, for example, the network topology is changed. Protection relays can have several predefined setting groups (SGs) depending on the number of possible configurations. However, centralized protection and control devices can store a limited number of setting groups, in many cases by far less than the number of possible network topologies. Therefore, in adaptive centralized protection schemes where online setting calculation is not feasible, a proper method should be used to cluster the different possible configurations and reduce their number to match or be fewer than the number of available SGs in relays. The offline calculated settings for each cluster can be stored in the centralized protection and control devices, which continuously monitor the status of circuit breakers (CBs) online. Then, upon detecting a change in the CB status, the corresponding SG will be activated. This paper presents three new methods for clustering network topologies, considering N-1 contingency in adaptive relay coordination. These methods are compared to the one in the literature and each other in terms of operation time delay of relays. Moreover, to mitigate false operations of relays due to unavailability of communication networks, a setting group is dedicated to the robust setting group. Finally, a practical implementation of the proposed method using IEC 61850 standard is illustrated using two schemes step by step. IEEE 14-bus is selected as a test system to evaluate the applicability of the proposed methods. The results, obtained by using MATLAB, DIgSILENT Programming Language, and hardware-in-the-loop setup show the effectiveness of the proposed methods in minimizing operating time delays of overcurrent relays.-
dc.description.notification© 2024 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent19-
dc.identifier.olddbid21380
dc.identifier.oldhandle10024/17987
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/2754
dc.identifier.urnURN:NBN:fi-fe2024082766500-
dc.language.isoeng-
dc.publisherElsevier-
dc.relation.doi10.1016/j.eswa.2024.124707-
dc.relation.funderBusiness Finland-
dc.relation.grantnumber6937/31/2021-
dc.relation.ispartofjournalExpert Systems with Applications-
dc.relation.issn1873-6793-
dc.relation.issn0957-4174-
dc.relation.urlhttps://doi.org/10.1016/j.eswa.2024.124707-
dc.relation.volume255-
dc.rightsCC BY 4.0-
dc.source.identifierWOS:001274643700001-
dc.source.identifierScopus:85198737485-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/17987
dc.subjectAdaptive protection-
dc.subjectCentralized protection-
dc.subjectClustering-
dc.subjectIEC 61850-
dc.subjectOvercurrent relays-
dc.subjectSetting group-
dc.subject.disciplinefi=Sähkötekniikka|en=Electrical Engineering|-
dc.titleReal-time hardware-in-the-loop approach for adaptive centralized protection schemes using clustering algorithms-
dc.type.okmfi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift|-
dc.type.publicationarticle-
dc.type.versionpublishedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Pashaei_Rastegar_Zandrazavi_Kauhaniemi_Laaksonen_2024.pdf
Size:
10.83 MB
Format:
Adobe Portable Document Format
Description:
Article

Kokoelmat