Experimental investigation on flue gas condensation heat recovery system integrated with heat pump and spray heat exchanger

annif.suggestionsheat recovery|heat exchangers|heat pumps|heat transfer|heat energy|natural gas|heating systems|emissions|combustion gases|energy efficiency|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p11189|http://www.yso.fi/onto/yso/p11705|http://www.yso.fi/onto/yso/p19364|http://www.yso.fi/onto/yso/p17700|http://www.yso.fi/onto/yso/p2054|http://www.yso.fi/onto/yso/p7053|http://www.yso.fi/onto/yso/p4775|http://www.yso.fi/onto/yso/p437|http://www.yso.fi/onto/yso/p15958|http://www.yso.fi/onto/yso/p8328en
dc.contributor.authorZhang, Qunli
dc.contributor.authorLiu, Tao
dc.contributor.authorCheng, Xuanrui
dc.contributor.authorGuo, Shuaifei
dc.contributor.authorZhang, Lin
dc.contributor.authorLü, Xiaoshu
dc.contributor.departmentfi=Ei tutkimusalustaa|en=No platform|-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.orcidhttps://orcid.org/0000-0002-1928-8580-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2024-04-10T07:54:32Z
dc.date.accessioned2025-06-25T13:13:50Z
dc.date.issued2024-02-20
dc.description.abstractTo deeply recover the flue gas condensation heat, a flue gas condensation heat recovery system that combines a compression heat pump (FGCHR-HP) is proposed. An experimental bench of the FGCHR-HP system was established to explore the thermal properties of the system under variable operating conditions. The experimental results show that when the inlet water temperature of the heat pump condensing heat exchanger is 50 °C and the flow rate is 40 L/min, the optimal experimental conditions are achieved. Under this working condition, the heat efficiency is 13.8 %, and the exhaust gas temperature is 26.9 °C. At the same time, the flue gas moisture recovery is up to 6.5–7.0 kg/hour, which is better than other boilers.The payback period of the FGCHR-HP system is 3.4 years. The system has achieved significant energy-saving and water-saving effects, and has certain promotion and application prospects.-
dc.description.notification©2024 Elsevier. This manuscript version is made available under the Creative Commons Attribution–NonCommercial–NoDerivatives 4.0 International (CC BY–NC–ND 4.0) license, https://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.embargo.lift2026-02-20
dc.embargo.terms2026-02-20
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent13-
dc.identifier.olddbid20318
dc.identifier.oldhandle10024/17150
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/1744
dc.identifier.urnURN:NBN:fi-fe2024041016074-
dc.language.isoeng-
dc.publisherElsevier-
dc.relation.doi10.1016/j.tsep.2024.102454-
dc.relation.funderBUCEA Doctor Graduate Scientific Research Ability Improvement Project-
dc.relation.grantnumberDG2023010-
dc.relation.ispartofjournalThermal Science and Engineering Progress-
dc.relation.issn2451-9049-
dc.relation.issn2451-9057-
dc.relation.urlhttps://doi.org/10.1016/j.tsep.2024.102454-
dc.relation.volume49-
dc.rightsCC BY-NC-ND 4.0-
dc.source.identifierScopus:85185719661-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/17150
dc.subjectFlue gas heat recovery-
dc.subjectGas boiler-
dc.subjectHeat pump-
dc.subjectSpray tower-
dc.subject.disciplinefi=Energiatekniikka|en=Energy Technology|-
dc.titleExperimental investigation on flue gas condensation heat recovery system integrated with heat pump and spray heat exchanger-
dc.type.okmfi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift|-
dc.type.publicationarticle-
dc.type.versionacceptedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Zhang_Liu_Cheng_Guo_Zhang_Lü_2024.pdf
Size:
1.22 MB
Format:
Adobe Portable Document Format
Description:
Article

Kokoelmat