Performance Comparison of PD Data Acquisition Techniques for Condition Monitoring of Medium Voltage Cables

annif.suggestionsmeasuring methods|condition monitoring|data acquisition|pulse|voltage|measuring instruments (devices)|cables|smart grids|reliability (general)|electrical power networks|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p20083|http://www.yso.fi/onto/yso/p15423|http://www.yso.fi/onto/yso/p2961|http://www.yso.fi/onto/yso/p3751|http://www.yso.fi/onto/yso/p15755|http://www.yso.fi/onto/yso/p3583|http://www.yso.fi/onto/yso/p188|http://www.yso.fi/onto/yso/p29493|http://www.yso.fi/onto/yso/p1629|http://www.yso.fi/onto/yso/p7753en
dc.contributor.authorShafiq, Muhammad
dc.contributor.authorKiitam, Ivar
dc.contributor.authorKauhaniemi, Kimmo
dc.contributor.authorTaklaja, Paul
dc.contributor.authorKütt, Lauri
dc.contributor.authorPalu, Ivo
dc.contributor.departmentfi=Ei tutkimusalustaa|en=No platform|-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.orcidhttps://orcid.org/0000-0002-2272-0899-
dc.contributor.orcidhttps://orcid.org/0000-0002-7429-3171-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2020-12-08T09:49:20Z
dc.date.accessioned2025-06-25T12:49:50Z
dc.date.available2020-12-08T09:49:20Z
dc.date.issued2020-08-18
dc.description.abstractAlready installed cables are aging and the cable network is growing rapidly. Improved condition monitoring methods are required for greater visibility of insulation defects in the cable networks. One of the critical challenges for continuous monitoring is the large amount of partial discharge (PD) data that poses constraints on the diagnostic capabilities. This paper presents the performance comparison of two data acquisition techniques based on phase resolved partial discharge (PRPD) and pulse acquisition (PA). The major contribution of this work is to provide an in-depth understanding of these techniques considering the perspective of randomness of the PD mechanism and improvements in the reliability of diagnostics. Experimental study is performed on the medium voltage (MV) cables in the laboratory environment. It has been observed that PRPD based acquisition not only requires a significantly larger amount of data but is also susceptible to losing the important information especially when multiple PD sources are being investigated. On the other hand, the PA technique presents improved performance for PD diagnosis. Furthermore, the use of the PA technique enables the efficient practical implementation of the continuous PD monitoring by reducing the amount of data that is acquired by extracting useful signals and discarding the silent data intervals.-
dc.description.notification© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent14-
dc.format.pagerange1-14-
dc.identifier.olddbid13121
dc.identifier.oldhandle10024/11733
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/998
dc.identifier.urnURN:NBN:fi-fe2020120899830-
dc.language.isoeng-
dc.publisherMDPI-
dc.relation.doi10.3390/en13164272-
dc.relation.ispartofjournalEnergies-
dc.relation.issn1996-1073-
dc.relation.issue16-
dc.relation.urlhttps://doi.org/10.3390/en13164272-
dc.relation.volume13-
dc.rightsCC BY 4.0-
dc.source.identifierWOS: 000567216400001-
dc.source.identifierScopus: 85090506512-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/11733
dc.subjectpartial discharges-
dc.subjectinsulation-
dc.subject.disciplinefi=Sähkötekniikka|en=Electrical Engineering|-
dc.subject.ysocondition monitoring-
dc.subject.ysodata acquisition-
dc.subject.ysocables-
dc.titlePerformance Comparison of PD Data Acquisition Techniques for Condition Monitoring of Medium Voltage Cables-
dc.type.okmfi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift|-
dc.type.publicationarticle-
dc.type.versionpublishedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Shafiq_Kiitam_Kauhaniemi_Taklaja_Kütt_Palu_2020.pdf
Size:
4.27 MB
Format:
Adobe Portable Document Format
Description:
Artikkeli

Kokoelmat