Power line signalling based earth fault location

dc.contributor.authorFarughian, Amir
dc.contributor.authorPoluektov, Anton
dc.contributor.authorPinomaa, Antti
dc.contributor.authorAhola, Jero
dc.contributor.authorKosonen, Antti
dc.contributor.authorKumpulainen, Lauri
dc.contributor.authorKauhaniemi, Kimmo
dc.contributor.departmentfi=Ei tutkimusalustaa|en=No platform|-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2019-06-18T12:51:38Z
dc.date.accessioned2025-06-25T12:27:06Z
dc.date.available2019-06-18T12:51:38Z
dc.date.issued2018
dc.description.abstractFault location in power networks is important as accurate information about the faulted line section expedites system restoration following a fault occurrence. A number of fault location methods have been proposed. Methods based on injecting a signal into the network and tracking it along the feeder appear to have received limited attention. In this study, fault location methods based on network signalling are examined. Two different types of approaches are presented. The first one is based on injection on a very low-frequency band, whereas the second one is based on utilising modern modulation technologies on low-frequency band, under 500 kHz, implemented on software-defined radios. The simulation results indicate the capability of the proposed methods in determining the location of a single phase-to-earth fault in medium-voltage distribution networks.-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.format.bitstreamtrue
dc.format.extent5-
dc.format.pagerange1155-1159-
dc.identifier.olddbid8425
dc.identifier.oldhandle10024/8195
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/253
dc.identifier.urnURN:NBN:fi-fe2019061820960-
dc.language.isoeng-
dc.publisherInstitution of Engineering and Technology-
dc.relation.doihttp://dx.doi.org/10.1049/joe.2018.0190-
dc.relation.ispartofjournalJournal of Engineering-
dc.relation.issn2051-3305-
dc.relation.issue15-
dc.relation.volume2018-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/8195
dc.titlePower line signalling based earth fault location-
dc.type.okmfi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift|-
dc.type.publicationarticle-