Thermal Impact of 5G Antenna Systems in Sandwich Walls

annif.suggestionsantennas|antenna systems|mobile communication networks|energy efficiency|energy consumption (energy technology)|heat transfer|electrical engineering|radio waves|construction engineering|wireless networks|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p16153|http://www.yso.fi/onto/yso/p16154|http://www.yso.fi/onto/yso/p12758|http://www.yso.fi/onto/yso/p8328|http://www.yso.fi/onto/yso/p2382|http://www.yso.fi/onto/yso/p17700|http://www.yso.fi/onto/yso/p1585|http://www.yso.fi/onto/yso/p5743|http://www.yso.fi/onto/yso/p20044|http://www.yso.fi/onto/yso/p24221en
dc.contributor.authorLu, Tao
dc.contributor.authorVähä-Savo, Lauri
dc.contributor.authorLü, Xiaoshu
dc.contributor.authorHaneda, Katsuyuki
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.orcidhttps://orcid.org/0000-0003-2917-6029-
dc.contributor.orcidhttps://orcid.org/0000-0002-1928-8580-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2024-01-08T12:27:16Z
dc.date.accessioned2025-06-25T13:11:01Z
dc.date.available2024-01-08T12:27:16Z
dc.date.issued2023-03-12
dc.description.abstractThe 5th generation (5G) cellular networks offer high speeds, low latency, and greater capacity, but they face greater penetration loss through buildings than 4G due to their higher frequency bands. To reduce this loss in energy-efficient buildings, a passive antenna system was developed and integrated into sandwich walls. However, the thermal effects of this system, which includes highly thermally conductive metals, require further study. In this research, three-dimensional heat transfer simulations were performed using COMSOL Multiphysics to determine the thermal transmittances (U-values) of 5G antenna walls. The results revealed that, using stainless steel as the connector material (current design), the U-value rose from 0.1496 (for the wall without antenna) to 0.156 W/m2K, leading to an additional heating loss per year of only 0.545 KWh/m2 in Helsinki. In contrast, with the previous design that used copper as the connector material, the U-value increased dramatically to 0.3 W/m2K, exceeding the National Building Code of Finland’s limit of 0.17 W/m2K and causing 12.8 KWh/m2 additional heat loss (23.5 times more than the current design). The current design significantly reduces thermal bridging effects. Additionally, three analytical methods were used to calculate antenna wall U-values: parallel paths, isothermal planes, and ISO 6946 combined. The isothermal planes method was found to be more accurate and reliable. The study also found that a wall unit cell with a single developed 5G antenna and a wall consisting of nine such cells arranged in a 3 × 3 grid pattern had the same U-values. Furthermore, areas affected by thermal bridging were typically smaller than the dimensions of a wall unit cell (150 mm × 150 mm).-
dc.description.notification© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent17-
dc.identifier.olddbid19718
dc.identifier.oldhandle10024/16723
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/1644
dc.identifier.urnURN:NBN:fi-fe202401081874-
dc.language.isoeng-
dc.publisherMDPI-
dc.relation.doi10.3390/en16062657-
dc.relation.funderAcademy of Finland-
dc.relation.grantnumber324023-
dc.relation.ispartofjournalEnergies-
dc.relation.issn1996-1073-
dc.relation.issue6-
dc.relation.urlhttps://doi.org/10.3390/en16062657-
dc.relation.volume16-
dc.rightsCC BY 4.0-
dc.source.identifierWOS:000955534700001-
dc.source.identifierScopus:85152088733-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/16723
dc.subject5G passive antenna system-
dc.subject5G antenna walls-
dc.subjectsandwich wall-
dc.subjectnumerical modeling-
dc.subjectparallel path method-
dc.subjectisothermal planes method-
dc.subjectISO 6946 combined method-
dc.subjectthermal transmittance-
dc.subject.disciplinefi=Energiatekniikka|en=Energy Technology|-
dc.titleThermal Impact of 5G Antenna Systems in Sandwich Walls-
dc.type.okmfi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift|-
dc.type.publicationarticle-
dc.type.versionpublishedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Lu_Vähä-Savo_Lü_Haneda_2023.pdf
Size:
1.06 MB
Format:
Adobe Portable Document Format
Description:
Artikkeli

Kokoelmat