An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard : Algorithm Proposal Using Offline Simulations
| annif.suggestions | electrical power networks|distribution of electricity|defects|supply of electricity|voltage|generators (devices)|reactive power|distributed generation|distributed systems|electric companies|en | en |
| annif.suggestions.links | http://www.yso.fi/onto/yso/p7753|http://www.yso.fi/onto/yso/p187|http://www.yso.fi/onto/yso/p543|http://www.yso.fi/onto/yso/p4956|http://www.yso.fi/onto/yso/p15755|http://www.yso.fi/onto/yso/p2546|http://www.yso.fi/onto/yso/p22054|http://www.yso.fi/onto/yso/p25903|http://www.yso.fi/onto/yso/p21082|http://www.yso.fi/onto/yso/p5562 | en |
| dc.contributor.author | Memon, Aushiq Ali | |
| dc.contributor.author | Kauhaniemi, Kimmo | |
| dc.contributor.department | fi=Ei tutkimusalustaa|en=No platform| | - |
| dc.contributor.faculty | fi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations| | - |
| dc.contributor.orcid | https://orcid.org/0000-0003-1290-6312 | - |
| dc.contributor.orcid | https://orcid.org/0000-0002-7429-3171 | - |
| dc.contributor.organization | fi=Vaasan yliopisto|en=University of Vaasa| | |
| dc.date.accessioned | 2020-11-23T08:58:24Z | |
| dc.date.accessioned | 2025-06-25T12:46:42Z | |
| dc.date.available | 2020-11-23T08:58:24Z | |
| dc.date.issued | 2020-10-13 | |
| dc.description.abstract | The IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the paper is to utilize the existing low-voltage ride through characteristic of distributed generators (DGs) with a reactive power supply during faults and communication between intelligent electronic devices (IEDs) at different locations for adaptive overcurrent protection. The adaptive overcurrent IEDs detect the faults with two different preplanned settings groups: lower settings for the islanded mode and higher settings for the grid-connected mode considering limited fault contributions from the converter-based DGs. Setting groups are changed to lower values quickly using the circuit breaker status signal (XCBR) after loss-of-mains, loss-of-DG or islanding is detected. The methods of fault detection and isolation for two different kinds of communication-based IEDs (adaptive/nonadaptive) are explained for three-phase faults at two different locations. The communication-based IEDs take decisions in a decentralized manner, using information about the circuit breaker status, fault detection and current magnitude comparison signals obtained from other IEDs. However, the developed algorithm can also be implemented with the centralized system. An adaptive overcurrent protection algorithm was evaluated with PSCAD (Power Systems Computer Aided Design) simulations, and results were found to be effective for the considered fault cases. | - |
| dc.description.notification | © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). | - |
| dc.description.reviewstatus | fi=vertaisarvioitu|en=peerReviewed| | - |
| dc.format.bitstream | true | |
| dc.format.content | fi=kokoteksti|en=fulltext| | - |
| dc.format.extent | 31 | - |
| dc.format.pagerange | 1-31 | - |
| dc.identifier.olddbid | 13000 | |
| dc.identifier.oldhandle | 10024/11587 | |
| dc.identifier.uri | https://osuva.uwasa.fi/handle/11111/898 | |
| dc.identifier.urn | URN:NBN:fi-fe2020112392364 | - |
| dc.language.iso | eng | - |
| dc.publisher | MDPI | - |
| dc.relation.doi | 10.3390/en13205316 | - |
| dc.relation.ispartofjournal | Energies | - |
| dc.relation.issn | 1996-1073 | - |
| dc.relation.issue | 20 | - |
| dc.relation.url | https://doi.org/10.3390/en13205316 | - |
| dc.relation.volume | 13 | - |
| dc.rights | CC BY 4.0 | - |
| dc.source.identifier | WOS: 000586871300001 | - |
| dc.source.identifier | Scopus: 85092893762 | - |
| dc.source.identifier | https://osuva.uwasa.fi/handle/10024/11587 | |
| dc.subject | AC microgrid | - |
| dc.subject | adaptive protection | - |
| dc.subject | IEC 61850 GOOSE protocol | - |
| dc.subject | substation automation | - |
| dc.subject.discipline | fi=Sähkötekniikka|en=Electrical Engineering| | - |
| dc.title | An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard : Algorithm Proposal Using Offline Simulations | - |
| dc.type.okm | fi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift| | - |
| dc.type.publication | article | - |
| dc.type.version | publishedVersion | - |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Osuva_Memon_Kauhaniemi_2020.pdf
- Size:
- 9.02 MB
- Format:
- Adobe Portable Document Format
- Description:
- Artikkeli