Factors affecting the performance of ventilation cavities in highly insulated assemblies

annif.suggestionsventilation|roofs|indoor air|moisture|facades|air conditioning|roofing|walls of buildings|insulation|volatile organic compounds|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p5431|http://www.yso.fi/onto/yso/p9278|http://www.yso.fi/onto/yso/p5433|http://www.yso.fi/onto/yso/p6453|http://www.yso.fi/onto/yso/p15728|http://www.yso.fi/onto/yso/p6628|http://www.yso.fi/onto/yso/p3038|http://www.yso.fi/onto/yso/p8066|http://www.yso.fi/onto/yso/p16134|http://www.yso.fi/onto/yso/p17386en
dc.contributor.authorViljanen, Klaus
dc.contributor.authorLü, Xiaoshu
dc.contributor.authorPuttonen, Jari
dc.contributor.departmentfi=Ei tutkimusalustaa|en=No platform|-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2022-03-30T13:34:39Z
dc.date.accessioned2025-06-25T13:31:47Z
dc.date.available2022-03-30T13:34:39Z
dc.date.issued2021-03-01
dc.description.abstractThe article presents experimental studies of typical Finnish highly insulated (HI) envelopes with thermal resistance values (R value) for the wall and roof inside the ventilation cavity between 7.7 and 8.1 m2K/W and 13 m2K/W, respectively. The conditions in the ventilation cavities were studied by using typical and increased R values for the exterior part of the cavity, which were 0.18 m2K/W and 1.57 m2K/W in the walls, and 0.13 m2K/W and 2.13 m2K/W for the roof. With higher exterior R values of 1.57 m2K/W and 2.13 m2K/W, the cavity temperature increased only after closing the inlet gap of the cavities. If the cavity inlet was closed, the restriction of the outlet gap from 20–25 mm to 10 mm had no significant effect on the temperatures. A closed ventilation inlet resulted in increased absolute humidity in the cavity, which indicates that the restriction of cavity ventilation should be made with care to avoid impairing the drying-out ability. The computational analysis showed that the optimal air change rates in the wall and roof cavities of HI structures were 4–40 1/h and 20 1/h, respectively. The conventional 22-mm-thick wood cladding enables safe cavity conditions in HI walls if the vapor barrier is vapor tight and other moisture sources are low. A lower heat flux and additional heat loss caused by cloudless sky at night support the observation that HI roofs have a higher moisture risk. In HI roofs, a conventional exterior R value of 0.13 m2K/W should at least be increased to the range of 0.3–0.4 m2K/W, which is achieved, for example, by a 20-mm-thick mineral wool board under the roofing. The use of mold-resistant materials in the ventilation cavity is recommended to mitigate the possible ramifications of the moisture behavior of HI roofs.-
dc.description.notification©2021 the Author(s). Published by SAGE Publications. https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent44-
dc.format.pagerange67-110-
dc.identifier.olddbid15757
dc.identifier.oldhandle10024/13761
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/2272
dc.identifier.urnURN:NBN:fi-fe2022033026224-
dc.language.isoeng-
dc.publisherSAGE Publications-
dc.relation.doi10.1177/1744259121995221-
dc.relation.funderPhD-program of Ramboll Foundation/Ramboll Finland-
dc.relation.funderAalto-Yliopisto-
dc.relation.funderSTARCLUB, Academy of Finland-
dc.relation.grantnumber324023-
dc.relation.ispartofjournalJournal of Building Physics-
dc.relation.issn1744-2583-
dc.relation.issn1744-2591-
dc.relation.issue1-
dc.relation.urlhttps://dx.doi.org/10.1177/1744259121995221-
dc.relation.volume45-
dc.rightsCC BY 4.0-
dc.source.identifierWOS:000626090500001-
dc.source.identifierScopus:85101930079-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/13761
dc.subjectanalytical model-
dc.subjectbuoyancy-
dc.subjectcladding-
dc.subjectmold-
dc.subjectroof-
dc.subjectsnow melting-
dc.subjectVentilation cavity-
dc.subjectwall-
dc.subject.disciplinefi=Energiatekniikka|en=Energy Technology|-
dc.titleFactors affecting the performance of ventilation cavities in highly insulated assemblies-
dc.type.okmfi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift|-
dc.type.publicationarticle-
dc.type.versionpublishedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Viljanen_Lü_Puttonen_2021.pdf
Size:
11.4 MB
Format:
Adobe Portable Document Format
Description:
Artikkeli

Kokoelmat