Investigation of Distribution Transformer Loss of Life in Electric Vehicles Parking Lot Integrated System

annif.suggestionselectric vehicles|temperature|air impurities and contaminants|electricity tariffs|air pollution|distribution of electricity|energy costs|electrical engineering|distribution|systems|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p27472|http://www.yso.fi/onto/yso/p2100|http://www.yso.fi/onto/yso/p3739|http://www.yso.fi/onto/yso/p14947|http://www.yso.fi/onto/yso/p5030|http://www.yso.fi/onto/yso/p187|http://www.yso.fi/onto/yso/p14948|http://www.yso.fi/onto/yso/p1585|http://www.yso.fi/onto/yso/p7415|http://www.yso.fi/onto/yso/p3358en
dc.contributor.authorSadati, S. Muhammad Bagher
dc.contributor.authorYazdani-Asrami, Mohammad
dc.contributor.authorShafie-khah, Miadreza
dc.contributor.authorOsório, Gerardo J.
dc.contributor.authorCatalão, João P. S.
dc.contributor.departmentVebic-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.orcidhttps://orcid.org/0000-0003-1691-5355-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2021-02-23T11:10:48Z
dc.date.accessioned2025-06-25T12:57:19Z
dc.date.available2022-10-19T15:01:40Z
dc.date.issued2020-08-07
dc.description.abstractNowadays, the operation of the smart distribution system (SDS) is more complicated with the penetration of electric vehicles (EVs), due to EVs' uncertainties as well as the capability of vehicle-to-grid (V2G). On the other hand, distribution transformers (DTs) which have to meet the demand of EVs are one of the essential components of SDS; indeed, their failure can lead to irreparable damage. The cause of most of these failures is overloading and high ambient temperature. The overloading increases the temperature of the various parts of the DTs, especially hot spot temperature (HST). Increasing this temperature reduces the nominal life of the DTs. With a high number of EVs in the future, and as a consequence high energy demand which has not been taken into account in proper operating program, it could lead to the overloading of DTs. So, in this paper, the loss of life (LOL) of a DT that feeds the residential loads and an EV parking lot (EV PL) is investigated. The maximization of the profit of the distribution system operator (DSO) is considered in two different parts i.e. with/without the appropriate operation coefficient (OC) of DT. Also, two different scenarios are applied i.e. charging mode (CM) of EVs and charging/discharging mode (CDM) of EVs. The results show that if the OC is not properly considered, the LOL of the transformers will be significantly high, implying a higher total ownership cost.-
dc.description.notification© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.embargo.lift2022-08-07
dc.embargo.terms2022-08-07
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent6-
dc.format.pagerange230-235-
dc.identifier.isbn978-1-7281-4218-0-
dc.identifier.olddbid13691
dc.identifier.oldhandle10024/12174
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/1217
dc.identifier.urnURN:NBN:fi-fe202102235738-
dc.language.isoeng-
dc.publisherIEEE-
dc.relation.conferenceInternational Conference on Compatibility, Power Electronics and Power Engineering-
dc.relation.doi10.1109/CPE-POWERENG48600.2020.9161684-
dc.relation.ispartof2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)-
dc.relation.ispartofseriesCompatibility in power electronics-
dc.relation.issn2166-9546-
dc.relation.issn2166-9538-
dc.relation.urlhttps://doi.org/10.1109/CPE-POWERENG48600.2020.9161684-
dc.source.identifierScopus: 85090848523-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/12174
dc.subjectDistribution transformer-
dc.subjectElectric vehicles parking lot-
dc.subjectLoss of life-
dc.subjectOperation coefficient-
dc.subject.disciplinefi=Sähkötekniikka|en=Electrical Engineering|-
dc.titleInvestigation of Distribution Transformer Loss of Life in Electric Vehicles Parking Lot Integrated System-
dc.type.okmfi=A4 Artikkeli konferenssijulkaisussa|en=A4 Peer-reviewed article in conference proceeding|sv=A4 Artikel i en konferenspublikation|-
dc.type.publicationarticle-
dc.type.versionacceptedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Sadati_Yazdani-Asrami_Shafie-khah_Osório_Catalão_2020.pdf
Size:
1.01 MB
Format:
Adobe Portable Document Format
Description:
Artikkeli

Kokoelmat