Analysis of Stationary- and Synchronous-Reference Frames for Three-Phase Three-Wire Grid-Connected Converter AC Current Regulators
| annif.suggestions | electrical power networks|electrical engineering|voltage|power electronics|transformers (electrical devices)|converters (electrical devices)|renewable energy sources|alternating current power|distribution of electricity|direct current|en | en |
| annif.suggestions.links | http://www.yso.fi/onto/yso/p7753|http://www.yso.fi/onto/yso/p1585|http://www.yso.fi/onto/yso/p15755|http://www.yso.fi/onto/yso/p16778|http://www.yso.fi/onto/yso/p3606|http://www.yso.fi/onto/yso/p8191|http://www.yso.fi/onto/yso/p20762|http://www.yso.fi/onto/yso/p19345|http://www.yso.fi/onto/yso/p187|http://www.yso.fi/onto/yso/p8116 | en |
| dc.contributor.author | Costa, Israel D. L. | |
| dc.contributor.author | Brandao, Danilo I. | |
| dc.contributor.author | Matakas Junior, Lourenço | |
| dc.contributor.author | Simões, Marcelo G. | |
| dc.contributor.author | Morais, Lenin M. F. | |
| dc.contributor.department | Vebic | - |
| dc.contributor.faculty | fi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations| | - |
| dc.contributor.orcid | https://orcid.org/0000-0003-4124-061X | - |
| dc.contributor.organization | fi=Vaasan yliopisto|en=University of Vaasa| | |
| dc.date.accessioned | 2022-01-03T13:25:35Z | |
| dc.date.accessioned | 2025-06-25T13:21:07Z | |
| dc.date.available | 2022-01-03T13:25:35Z | |
| dc.date.issued | 2021-12-10 | |
| dc.description.abstract | The current state of the art shows that unbalance and distortion on the voltage waveforms at the terminals of a grid-connected inverter disturb its output currents. This paper compares AC linear current regulators for three-phase three-wire voltage source converters with three different reference frames, namely: (1) natural (abc), (2) orthogonal stationary (αβ), and (3) orthogonal synchronous (dq). The quantitative comparison analysis is based on mathematical models of grid disturbances using the impedance-based analysis, the computational effort assessment, as well as the steady-state and transient performance evaluation based on experimental results. The control scheme devised in the dq-frame has the highest computational effort and inferior performance under negative-sequence voltage disturbances, whereas it shows superior performance under positive-sequence voltages among the reference frames evaluated. In contrast, the stationary natural frame abc has the lowest computational effort due to its straightforward implementation, with similar results in terms of steady-state and transient behavior. The αβ-frame is an intermediate solution in terms of computational cost. | - |
| dc.description.abstract | This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)—Finance Code 001. | - |
| dc.description.notification | © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | - |
| dc.description.reviewstatus | fi=vertaisarvioitu|en=peerReviewed| | - |
| dc.format.bitstream | true | |
| dc.format.content | fi=kokoteksti|en=fulltext| | - |
| dc.format.extent | 16 | - |
| dc.identifier.olddbid | 15287 | |
| dc.identifier.oldhandle | 10024/13360 | |
| dc.identifier.uri | https://osuva.uwasa.fi/handle/11111/1975 | |
| dc.identifier.urn | URN:NBN:fi-fe202201031082 | - |
| dc.language.iso | eng | - |
| dc.publisher | MDPI | - |
| dc.relation.doi | 10.3390/en14248348 | - |
| dc.relation.ispartofjournal | Energies | - |
| dc.relation.issn | 1996-1073 | - |
| dc.relation.issue | 24 | - |
| dc.relation.url | https://doi.org/10.3390/en14248348 | - |
| dc.relation.volume | 14 | - |
| dc.rights | CC BY 4.0 | - |
| dc.source.identifier | Scopus: 85121287917 | - |
| dc.source.identifier | https://osuva.uwasa.fi/handle/10024/13360 | |
| dc.subject | coordinated reference frame | - |
| dc.subject | current control | - |
| dc.subject | grid-connected converter | - |
| dc.subject | three-phase converter | - |
| dc.subject | unbalance | - |
| dc.subject.discipline | fi=Sähkötekniikka|en=Electrical Engineering| | - |
| dc.title | Analysis of Stationary- and Synchronous-Reference Frames for Three-Phase Three-Wire Grid-Connected Converter AC Current Regulators | - |
| dc.type.okm | fi=A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä|en=A1 Peer-reviewed original journal article|sv=A1 Originalartikel i en vetenskaplig tidskrift| | - |
| dc.type.publication | article | - |
| dc.type.version | publishedVersion | - |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Osuva_Costa_Brandao_Matakas Junior_Simões_Morais_2021.pdf
- Size:
- 3.37 MB
- Format:
- Adobe Portable Document Format
- Description:
- Artikkeli
