Electro-magnetic Sensors for Online Condition Monitoring of Medium Voltage Cables
| annif.suggestions | sensors|condition monitoring|electricity measurement technology|measurement|cables|detectors|parallel publishing|measuring technology|mathematical models|voltage|en | en |
| annif.suggestions.links | http://www.yso.fi/onto/yso/p11460|http://www.yso.fi/onto/yso/p15423|http://www.yso.fi/onto/yso/p9764|http://www.yso.fi/onto/yso/p4794|http://www.yso.fi/onto/yso/p188|http://www.yso.fi/onto/yso/p4220|http://www.yso.fi/onto/yso/p27097|http://www.yso.fi/onto/yso/p5635|http://www.yso.fi/onto/yso/p11401|http://www.yso.fi/onto/yso/p15755 | en |
| dc.contributor.author | Shafiq, Muhammad | |
| dc.contributor.author | Kauhaniemi, Kimmo | |
| dc.contributor.author | Hussain, Amjad | |
| dc.contributor.author | Kutt, Lauri | |
| dc.contributor.department | fi=Ei tutkimusalustaa|en=No platform| | - |
| dc.contributor.faculty | fi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations| | - |
| dc.contributor.orcid | https://orcid.org/0000-0002-2272-0899 | - |
| dc.contributor.orcid | https://orcid.org/0000-0002-7429-3171 | - |
| dc.contributor.organization | fi=Vaasan yliopisto|en=University of Vaasa| | |
| dc.date.accessioned | 2021-03-24T09:04:53Z | |
| dc.date.accessioned | 2025-06-25T12:55:30Z | |
| dc.date.available | 2021-03-24T09:04:53Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | Increased use of medium voltage (MV) cables demands for efficient condition monitoring in order to carry out timely predictive maintenance especially during incipient fault conditions emerging due to insulation degradation. This paper presents a comparison of the design and performance parameters of the Rogowski coil and high frequency current transformer sensors for measurement of partial discharge (PD) signals emitted from the PD defects. This work is performed in the laboratory environment that provides a practical approach for developing electromagnetic sensor for PD measurements. | - |
| dc.description.notification | ©2020 the Authors. Published by AMA Association for Sensors & Measurement. | - |
| dc.description.reviewstatus | fi=vertaisarvioitu|en=peerReviewed| | - |
| dc.format.bitstream | true | |
| dc.format.content | fi=kokoteksti|en=fulltext| | - |
| dc.format.extent | 2 | - |
| dc.format.pagerange | 315-316 | - |
| dc.identifier.isbn | 978-3-9819376-2-6 | - |
| dc.identifier.olddbid | 13854 | |
| dc.identifier.oldhandle | 10024/12298 | |
| dc.identifier.uri | https://osuva.uwasa.fi/handle/11111/1154 | |
| dc.identifier.urn | URN:NBN:fi-fe202103248192 | - |
| dc.language.iso | eng | - |
| dc.publisher | AMA Association for Sensors & Measurement | - |
| dc.relation.conference | Sensor and Measurement Science International | - |
| dc.relation.doi | 10.5162/SMSI2020/E6.4 | - |
| dc.relation.ispartof | Proceedings of SMSI - Sensor and Measurement Science International | - |
| dc.relation.url | https://doi.org/10.5162/SMSI2020/E6.4 | - |
| dc.source.identifier | https://osuva.uwasa.fi/handle/10024/12298 | |
| dc.subject | Distribution Network | - |
| dc.subject | Electromagnetic sensor | - |
| dc.subject | Medium voltage cable | - |
| dc.subject | partial discharge | - |
| dc.subject.discipline | fi=Sähkötekniikka|en=Electrical Engineering| | - |
| dc.subject.yso | condition monitoring | - |
| dc.title | Electro-magnetic Sensors for Online Condition Monitoring of Medium Voltage Cables | - |
| dc.type.okm | fi=A4 Artikkeli konferenssijulkaisussa|en=A4 Peer-reviewed article in conference proceeding|sv=A4 Artikel i en konferenspublikation| | - |
| dc.type.publication | article | - |
| dc.type.version | publishedVersion | - |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Osuva_Shafiq_Kauhaniemi_Hussain_Kutt_2020.pdf
- Size:
- 1.05 MB
- Format:
- Adobe Portable Document Format
- Description:
- Artikkeli
