Research on the indoor temperature regulation characteristics of a nearly zero energy building with the nonlinear heat capacity building components : A simple model

annif.suggestionsindoor air|People's Republic of China|buildings|energy efficiency|ventilation|temperature|heat capacity|air conditioning|heating (spaces)|heat recovery|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p5433|http://www.yso.fi/onto/yso/p104984|http://www.yso.fi/onto/yso/p1786|http://www.yso.fi/onto/yso/p8328|http://www.yso.fi/onto/yso/p5431|http://www.yso.fi/onto/yso/p2100|http://www.yso.fi/onto/yso/p11389|http://www.yso.fi/onto/yso/p6628|http://www.yso.fi/onto/yso/p4777|http://www.yso.fi/onto/yso/p11189en
dc.contributor.authorZhang, Qunli
dc.contributor.authorLiu, Yimo
dc.contributor.authorZhang, Qiuyue
dc.contributor.authorWang, Gang
dc.contributor.authorLü, Xiaoshu
dc.contributor.departmentfi=Ei tutkimusalustaa|en=No platform|-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.orcidhttps://orcid.org/0000-0002-1928-8580 View this author’s ORCID profile-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2023-08-29T06:27:07Z
dc.date.accessioned2025-06-25T12:52:10Z
dc.date.issued2023-07-13
dc.description.abstractWith establishment of global carbon reduction targets, energy conservation and emission reduction of building is imperative. By passive building design method, nearly zero energy buildings (nZEB) can decrease building energy consumption requirements. To reduce indoor temperature fluctuation of the nZEB in heating season, the conventional energy storage materials (CESM) or phase change materials (PCM) are utilized in the building components for thermal storage. The heat capacity of the PCM was simplified as ideal nonlinear heat capacity. To reveal the indoor temperature distribution characteristic in the nZEB affected by the building components with or without the nonlinear heat capacity, a simplified mathematical model was established. Several evaluation indicators were put forward to describe indoor temperature regulation difference between the CESM and the PCM. The results show that indoor temperature distribution characteristics of the nZEB with PCM was significantly different with that of the CESM building. The maximum indoor temperature distribution frequency of the PCM building is much larger than that of the CESM building. The maximum indoor temperature distribution frequency of PCM building was more concentrated and occurred close to the phase transition temperature. The maximum indoor temperature distribution frequency of the CESM is not exceed 10%, however, that of the PCM building can reach 42% in the same work condition. The maximum indoor temperature distribution frequency, the indoor comfort guarantee ratio and the latent heat utilization time ratio of the PCM building can be obviously increased by selecting the phase transition temperature close to the average indoor temperature in the heating season. The study work represent that the PCM building components with the nonlinear heat capacity can regulate the indoor temperature distribution frequency by change phase transition temperature.-
dc.description.notification©2023 Elsevier. This manuscript version is made available under the Creative Commons Attribution–NonCommercial–NoDerivatives 4.0 International (CC BY–NC–ND 4.0) license, https://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.description.reviewstatusfi=vertaisarvioitu|en=peerReviewed|-
dc.embargo.lift2025-07-13
dc.embargo.terms2025-07-13
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent15-
dc.identifier.olddbid18969
dc.identifier.oldhandle10024/16150
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/1053
dc.identifier.urnURN:NBN:fi-fe20230829111902-
dc.language.isoeng-
dc.publisherElsevier-
dc.relation.doi10.1016/j.jobe.2023.106850-
dc.relation.funderThe Graduate Innovation Project of Beijing University of Civil Engineering and Architecture-
dc.relation.grantnumber31081020005-
dc.relation.ispartofjournalJournal of Building Engineering-
dc.relation.issn2352-7102-
dc.relation.urlhttps://doi.org/10.1016/j.jobe.2023.106850-
dc.relation.volume76-
dc.rightsCC BY-NC-ND 4.0-
dc.source.identifierScopus:85164693701-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/16150
dc.subjectPhase change material-
dc.subjectNearly zero energy buildings-
dc.subjectThermal storage-
dc.subjectIndoor environment-
dc.subject.disciplinefi=Energiatekniikka|en=Energy Technology|-
dc.titleResearch on the indoor temperature regulation characteristics of a nearly zero energy building with the nonlinear heat capacity building components : A simple model-
dc.type.publicationarticle-
dc.type.versionacceptedVersion-

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Osuva_Zhang_Liu_Zhang_Wang_Lü_2023.pdf
Size:
1.17 MB
Format:
Adobe Portable Document Format
Description:
Artikkeli

Kokoelmat