Fault type and location detection in islanded microgrid with different control methods based converters

annif.suggestionselectrical power networks|distribution of electricity|defects|transformers (electrical devices)|supply of electricity|frequency changers|electric machines|parallel publishing|history|Finland|enen
annif.suggestions.linkshttp://www.yso.fi/onto/yso/p7753|http://www.yso.fi/onto/yso/p187|http://www.yso.fi/onto/yso/p543|http://www.yso.fi/onto/yso/p3606|http://www.yso.fi/onto/yso/p4956|http://www.yso.fi/onto/yso/p22720|http://www.yso.fi/onto/yso/p3357|http://www.yso.fi/onto/yso/p27097|http://www.yso.fi/onto/yso/p1780|http://www.yso.fi/onto/yso/p94426en
dc.contributor.authorLaaksonen, Hannu
dc.contributor.authorKauhaniemi, Kimmo
dc.contributor.departmentfi=Ei tutkimusalustaa|en=No platform|-
dc.contributor.facultyfi=Tekniikan ja innovaatiojohtamisen yksikkö|en=School of Technology and Innovations|-
dc.contributor.organizationfi=Vaasan yliopisto|en=University of Vaasa|
dc.date.accessioned2020-06-29T12:45:05Z
dc.date.accessioned2025-06-25T12:43:16Z
dc.date.available2020-06-29T12:45:05Z
dc.date.issued2007-05-21
dc.description.abstractIn this paper the fault type and location detection in an islanded low voltage (LV) distribution network based microgrid with converters applying different control methods is studied. In the future most of the distributed generation (DG) units in microgrids will be connected to network through power electronic interfaces (e.g. converters) which usually have limited capability to feed fault current due to power devices protection reasons.Also converter control methods affect to the converter fault behavior. This means that during the faults the converter cannot feed larger current than the nominal current of it or it tries to keep active power fed to grid on the reference value, so that the current of converter increases to a certain limit. Simulations show that protection of islandedmicrogrid with converters could be based on changes in phase voltages and voltage RMS values at the connection points of DG units. But, due to different control methods of converters, the fault location estimation is not that simple in every case.The simulation studies are made with PSCAD simulation software package.-
dc.description.reviewstatusfi=vertaisarvioimaton|en=nonPeerReviewed|-
dc.format.bitstreamtrue
dc.format.contentfi=kokoteksti|en=fulltext|-
dc.format.extent4-
dc.identifier.olddbid12458
dc.identifier.oldhandle10024/11254
dc.identifier.urihttps://osuva.uwasa.fi/handle/11111/787
dc.identifier.urnURN:NBN:fi-fe2020062946219-
dc.language.isoeng-
dc.publisherCIRED-
dc.relation.conferenceInternational Conference on Electricity Distribution (CIRED)-
dc.relation.ispartofCIRED - 19th International Conference on Electricity Distribution, Vienna, 21-24 May 2007-
dc.relation.ispartofseriesConference proceedings CIRED-
dc.relation.issn2312-7996-
dc.relation.numberinseries0372-
dc.relation.urlhttps://pdfs.semanticscholar.org/4b79/9d6d6d1d58f26b0ee4739b691e7b5d53a3d6.pdf-
dc.source.identifierhttps://osuva.uwasa.fi/handle/10024/11254
dc.subject.disciplinefi=Sähkötekniikka|en=Electrical Engineering|-
dc.subject.ysoelectrical power networks-
dc.subject.ysodistribution of electricity-
dc.subject.ysodefects-
dc.subject.ysotransformers (electrical devices)-
dc.subject.ysosupply of electricity-
dc.subject.ysofrequency changers-
dc.subject.ysoelectric machines-
dc.subject.ysoparallel publishing-
dc.subject.ysohistory-
dc.subject.ysoFinland-
dc.titleFault type and location detection in islanded microgrid with different control methods based converters-
dc.type.okmfi=B3 Vertaisarvioimaton artikkeli konferenssijulkaisussa|en=B3 Non-refereed article in conference proceeding|sv=B3 Icke-referentgranskad artikel i konferenspublikation|-
dc.type.publicationconferenceObject-