Co-operation of electricity and natural gas systems including electric vehicles and variable renewable energy sources based on a continuous-time model approach

Nikoobakhta, Ahmad; Aghaei, Jamshi; Shafie-khah, Miadreza; Catalão, João P.S. (2020-06-01)

 
Katso/Avaa
article (2.392Mb)
Lataukset: 

URI
https://doi.org/10.1016/j.energy.2020.117484

Nikoobakhta, Ahmad
Aghaei, Jamshi
Shafie-khah, Miadreza
Catalão, João P.S.
Elsevier
01.06.2020
doi:10.1016/j.energy.2020.117484
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2020060540812

Kuvaus

vertaisarvioitu
©2020 Elsevier Ltd. This manuscript version is made available under the Creative Commons Attribution–NonCommercial–NoDerivatives 4.0 International (CC BY–NC–ND 4.0) license, https://creativecommons.org/licenses/by-nc-nd/4.0/
Tiivistelmä
This paper proposes a stochastic framework to augment the integration of variable renewable energy sources (VRESs) in power system scheduling. In this way, the fast-response capability of gas-fired generator units (GFGUs) and vehicle-to-grid (V2G) capability of electric vehicles (EVs) can play important roles in large-scale integration of VRESs. However, the growth of GFGUs utilization can increase the grade of interdependency between power and natural gas systems. In this condition, the power system tends to demand more reliability and flexibility from the natural gas system, which creates new challenges in power system scheduling. The likely significant growth of EVs can solve this challenge and reduce the correlation between power and natural gas systems, bringing new opportunities for power system scheduling. However, a considerable literature in the field of operation of GFGUs and EVs has only focused on using the hourly discrete time model (HDTM). Undoubtedly, the major limitation of HDTM is its inability to handle the fast sub-hourly dispatch of GFGUs and energy storage capability of EVs. Accordingly, in this paper, this limitation has been solved by the operation of both energy systems with a continuous time model (CTM). The reliability test system with a ten-node gas transmission system has been analysed to show the effectiveness of the proposed problem.